Model
| IS-300A-00-00 |
IS-300A-00-01 |
Power requirements (fixed at factory)
| 3-phase, 200-240 VAC ±10% (50/60 Hz) |
3-phase, 380–480 VAC ±10% (50/60Hz) |
Max. output current
| 300 A (peak value) | 300 A (peak value) |
Duty cycle
| 300 A @ 4.4% 200 A @ 10%, 100 A @ 35%, 45 A @ 100% | 300 A @ 4.4% 200 A @ 10%, 100 A @ 35%, 45 A @ 100% |
Number of schedules
| 255 | 255 |
Output frequency
| 600 Hz~3 kHz (in 100 Hz increments) |
600 Hz~3 kHz (in 100 Hz increments) |
Control method
| Primary constant-current RMS / Secondary constant-current RMS / Secondary constant-power RMS / primary constant-current PEAK / Secondary constant-voltage RMS / Constant-phase control |
Primary constant-current RMS / Secondary constant-current RMS / Secondary constant-power RMS / primary constant-current PEAK / Secondary constant-voltage RMS / Constant-phase control |
Timer setting range
| Millisecond mode |
Cycle mode |
Timer setting range: Squeeze delay
| 0000~9999 ms | 000~999 cyc |
Timer setting range: Squeeze
| 0000~9999 ms | 000~999 cyc |
Timer setting range: Up-Slope 1,2,3
| 000~999 ms |
00~50 ms |
Timer setting range: Weld 1, 2, 3
| 000~999 ms | 00~50 ms |
Timer setting range: Down-Slope 1,2,3
| 000~999 ms | 00~50 ms |
Timer setting range: Cool 1,2
| 000~999 ms | 000~999 ms |
Timer setting range: Hold
| 0000~20000 ms | 000~999 ms |
Timer setting range: Off
| 0 or 10~9990 ms |
00~99 ms |
Transformer turns ration
| 1.0~199.9 |
1.0~199.9 |
Pulsation setting
| 01~19 |
01~19 |
Valve setting
| 2 |
2 |
Setting range: Constant current
| 0.05~ 20.0 kA |
0.05~ 20.0 kA |
Setting range: Constant power
| .05~20.0 kW |
.05~20.0 kW |
Setting range: Constant voltage
| 0.20~9.99 V |
0.20~9.99 V |
Setting range: Constant Phase
| 10.0~99.9% | 10.0~99.9% |
Current monitor
| 00.0~99.9 kA / 0.00~9.99 kA |
00.0~99.9 kA / 0.00~9.99 kA |
Power monitor
| 000.0~999.9 kW / 00.00~99.99 kW |
000.0~999.9 kW / 00.00~99.99 kW |
Voltage monitor
| 0.00~9.99 V | 0.00~9.99 V |
Pulse width monitor
| HIGH 10.0~100% | HIGH 10.0~100% |
Cooling method
| Forced air cooling |
Forced air cooling |
Data communication
| RS-232C (one-way communication) / RS-485 (bidirectional communication) |
RS-232C (one-way communication) / RS-485 (bidirectional communication) |
Corresponding transformer
| IT-1040-3 |
(500V) IT-4040-3 IT-4085-3, IT-4140-3 (650V) IT-1040-3, IT-1085-3, IT-1140-3 |
Dimensions (LxWxH)
| 574.0 mm x 172.7 mm x 269.2 mm 22.6 (in x 6.8 in x 10.6 in) |
574.0 mm x 172.7 mm x 269.2 mm 22.6 (in x 6.8 in x 10.6 in) |
Weight
| 16.5 kg (36.4 lbs) | 16.5 kg (36.4 lbs) |