IS-Q3000A
| IS-Q6000A
| IS-Q250A
| IS-Q500A
|
Performance range |
0,75kA – 1,5 kA - 3 kA |
6 kA |
10 kA |
20 kA |
Weld current types |
Controlled DC inverter current |
Controlled DC inverter current |
AC or DC inverter |
Features |
Inverter with integrated power on button, Performance and Control Electronics, Voltage control cable und removable Display MFT1 (optional: AWS3-Display) and additional: compact version w/integrated transformer, voltage sensor cable | Inverter with integrated power on button, Performance and Control Electronics, Voltage control cable und removable Display MFT1 (optional: AWS3-Display) and additional: Compact version w/integrated transformer, voltage sensor cable | Inverter with integrated power on button, Performance and Control Electronics, Voltage control cable und removable Display MFT1 (optional: AWS3-Display) and additional: Separate DC- or AC- transformer | Inverter with integrated power on button, Performance and Control Electronics, Voltage control cable und removable Display MFT1 (optional: AWS3-Display) and additional: Separate DC- or AC- transformer, external main fuse and net filter |
Options |
19“ plug-in unit without main unit |
19“ plug-in unit ithout main unit |
19“ plug-in unit without main unit |
19“ plug-in unit without main unit |
Control / control mode |
Current, voltage or power feedback control, independently adjustable independently for each pulse, APC (Active Part Conditioner) function and current, voltage, performance and energy limits |
Current, voltage or power feedback control, independently adjustable independently for each pulse, APC (Active Part Conditioner) function and current, voltage, performance and energy limits | Current, voltage or power feedback control, independently adjustable independently for each pulse, APC (Active Part Conditioner) function and current, voltage, performance and energy limits |
Current, voltage or power feedback control, independently adjustable independently for each pulse, APC (Active Part Conditioner) function and current, voltage, performance and energy limits |
Programmable weld schedules / external weld schedule selection |
99 at single axis; 49 per head at dual axis |
99 at single axis; 49 per head at dual axis |
99 at single axis; 49 per head at dual axis |
99 at single axis; 49 per head at dual axis |
# of weld pulses |
1st and/or 2nd pulse, 2nd pulse can be repeated max 10 times (decrease adjustable down to 1% of 2nd pulse) |
1st and/or 2nd pulse, 2nd pulse can be repeated max 10 times (decrease adjustable down to 1% of 2nd pulse) |
1st and/or 2nd pulse, 2nd pulse can be repeated max 10 times (decrease adjustable down to 1% of 2nd pulse) |
1st and/or 2nd pulse, 2nd pulse can be repeated max 10 times (decrease adjustable down to 1% of 2nd pulse) |
Weld pulse control |
Up slope, weld-time, down-slope, break time, impuls cycle |
Up slope, weld-time, down-slope, break time, impuls cycle |
Up slope, weld-time, down-slope, break time, impuls cycle |
Up slope, weld-time, down-slope, break time, impuls cycle |
Current measurement |
Integrated toroidal coil (Rogowski coil) |
Integrated toroidal coil (Rogowski coil) |
external toroidal coil |
external toroidal coil |
Voltage measurement |
Potential free, external connection (X10 axis/head 1; X11 axis/head 2) |
Potential free, external connection (X10 axis/head 1; X11 axis/head 2) |
Potential free, external connection (X10 axis/head 1; X11 axis/head 2) |
Potential free, external connection (X10 axis/head 1; X11 axis/head 2) |
Limit values |
Display with limit exceeding upper and lower limit, time limit, welding energy limit with sensitive components (weld to limit) |
Display with limit exceeding upper and lower limit, time limit, welding energy limit with sensitive components (weld to limit) |
Display with limit exceeding upper and lower limit, time limit, welding energy limit with sensitive components (weld to limit) |
Display with limit exceeding upper and lower limit, time limit, welding energy limit with sensitive components (weld to limit) |
Out of limit error message |
Text indication with limit and device errors; monitoring limits for U, I or P; + and – tolerance windows individually adjustable |
Text indication with limit and device errors; monitoring limits for U, I or P; + and – tolerance windows individually adjustable |
Text indication with limit and device errors; monitoring limits for U, I or P; + and – tolerance windows individually adjustable | Text indication with limit and device errors; monitoring limits for U, I or P; + and – tolerance windows individually adjustable |
Parts check |
Test pulse for part detection (pre-weld-check) | Test pulse for part detection (pre-weld-check) | Test pulse for part detection (pre-weld-check) |
Test pulse for part detection (pre-weld-check) |
Operation |
One button toggle wheel, monochrome display, Optional: coloured OP-AWS3-A Display, Profibus or Ethernet IP |
One button toggle wheel, monochrome display, Optional: coloured OP-AWS3-A Display, Profibus or Ethernet IP |
One button toggle wheel, monochrome display, Optional: coloured OP-AWS3-A Display, Profibus or Ethernet IP |
One button toggle wheel, monochrome display, Optional: coloured OP-AWS3-A Display, Profibus or Ethernet IP |
EU Certification |
CE Compliant | CE Compliant |
CE Compliant |
CE Compliant |
Continuous sound pressure level |
The equivalent continuous sound pressure level rated A is below 70 dB. Sound pressure levels may vary depending on the welding material and the environmental conditions. If necessary consult an acoustic specialist. |
The equivalent continuous sound pressure level rated A is below 70 dB. Sound pressure levels may vary depending on the welding material and the environmental conditions. If necessary consult an acoustic specialist. |
The equivalent continuous sound pressure level rated A is below 70 dB. Sound pressure levels may vary depending on the welding material and the environmental conditions. If necessary consult an acoustic specialist. |
The equivalent continuous sound pressure level rated A is below 70 dB. Sound pressure levels may vary depending on the welding material and the environmental conditions. If necessary consult an acoustic specialist. |
Electrical data |
Supply voltage |
3x 400 VAC, ± 10%, PE; 3x 230 V (optional), ISQ20-MFC 19 ± 10%, PE : non-heating, 3 pole connector |
3x 400 VAC, ± 10%, PE; 3x 230 V (optional), ± 10%, PE ISQ20-MFC 19”: non-heating, 3 pole connector |
3x 400 VAC, ± 10%, PE | 3x 400 VAC, ± 10%, PE |
Mains frequency |
50 - 60 Hz |
50 - 60 Hz |
50 - 60 Hz |
50 - 60 Hz |
Fusing |
with 400 V: 3x 16 A, delayed; with 230 V (optional): 3x 32A, delayed |
with 400 V: 3x 16 A, delayed; with 230 V (optional): 3x 32A, delayed |
3 x 32A, delayed | 3 x 125A, delayed (external) |
Connecting cable |
with 400 V: 4 x 2.5 mm², with 230 V (optional): 4 x 4 mm² | with 400 V: 4 x 2.5 mm², with 230 V (optional): 4 x 4 mm² | 4 x 6 mm² | 4 x 50 mm² shielded |
Protection class |
IP30 ISQ20-MFC 19“: depending on housing |
IP30 ISQ20-MFC 19“: depending on housing |
IP30 ISQ20-MFC 19“: depending on housing |
IP30 ISQ20-MFC 19“: depending on housing |
Welding transformer |
internal for 3 kA |
internal for 6 kA |
External DC: IT-60X AC: TRM3 14-9 V MT40X-530 |
External: DC: IT-113 AC: upon request |
Power data |
IS-Q3000A |
IS-Q6000A |
IS-Q250A |
IS-Q500A |
Connected load |
11 kVA |
11 kVA |
22 kVA |
85 kVA |
Switching frequency |
max. 20 kHz |
max. 14 kHz |
1 – 10 kHz (AC) 1 – 5 kHz (DC) depending on primary current |
1 – 10 kHz (AC) 1 – 5 kHz (DC) depending on primary current |
Output frequency |
40 kHz |
26 kHz |
1 – 10 kHz (AC) 2 – 10 kHz (DC) |
1 – 10 kHz (AC) 2 – 10 kHz (DC) |
Fundamental frequency AC |
--- |
--- |
AC: 50 – 250 Hz |
AC: 50 – 250 Hz |
Rated power |
12 kVA |
24 kVA |
40 kVA (DC) |
25 kVA (AC), DC with IT 113: 75 kVA; dep on transformer |
Max weld current |
3 kA with 5% d.r. |
6 kA with 5% d.r. |
10 kA with 8% d.r. DC only |
20 kA with 15% d.r. DC only |
Max. weld period |
320 ms/pulse | 320 ms/pulse |
640 ms/pulse | 320 ms/pulse |
Min. weld period |
0.7 ms |
0.7 ms |
DC: 0,7 ms AC: 0,5 x impuls frequency |
DC: 0,7 ms AC: 0,5 x impuls frequency |
Rated output current |
2 kA 11% d.r. |
3 kA 20% d.r. |
depending on transformer |
depending on transformer |
Min. terminal voltage |
4 V with 3 kA | 4 V with 6 kA | DC: 4 V with 10 kA AC: dep on transformer |
DC with IT 113: 3 V at 25 kA; AC: dep on transformer |
Max. open-circuit voltage |
10 V | 10 V |
DC: 10 V AC: dep on transformer |
DC: 11 V AC: dep on transformer |
Interface |
Secondary connections |
CU-rails, 2 x M8 internal thread |
CU-rails, 2 x M8 internal thread |
Depending on transformer |
Depending on transformer |
Analog input |
Pressure sensor for proportional valve |
Pressure sensor for proportional valve |
Pressure sensor for proportional valve |
Pressure sensor for proportional valve |
Analog output |
Proportional valve control |
Proportional valve control |
Proportional valve control |
Proportional valve control |
Digital interfaces |
via D-Sub-9 socket; welding data output in ASCII-compatible printing format |
via D-Sub-9 socket; welding data output in ASCII-compatible printing format |
via D-Sub-9 socket; welding data output in ASCII-compatible printing format |
via D-Sub-9 socket; welding data output in ASCII-compatible printing format |
Binary interface input |
Start, quick stop, pressure switch, proximity switches, pressure sensor |
Start, quick stop, pressure switch, proximity switches, pressure sensor |
Start, quick stop, pressure switch, proximity switches, pressure sensor |
Start, quick stop, pressure switch, proximity switches, pressure sensor |
Binary interface output |
a.o. stepping contact, counter, set point deviation, closing stroke, welding pressure, air valves |
a.o. stepping contact, counter, set point deviation, closing stroke, welding pressure, air valves |
a.o. stepping contact, counter, set point deviation, closing stroke, welding pressure, air valves |
a.o. stepping contact, counter, set point deviation, closing stroke, welding pressure, air valves |
Operation |
Cooling |
Forced air ventilation, temperature controlled |
Forced air ventilation, temperature controlled |
Transformer water cooled | Inverter and transformer water cooled |
Moisture |
40 - 70 %, not condensating |
40 - 70 %, not condensating | 40 - 70 %, not condensating |
40 - 70 %, not condensating |
Ambient Temperature |
0 - 40°C |
0 - 40°C |
0 - 40°C | 0 - 40°C |
. |
IS-Q3000A | IS-Q6000A |
IS-Q250A | IS-Q500A |
Weight inverter |
approx 33 kg |
approx 43 kg | approx 20 kg (without transforner) |
approx 31 kg (without transforner etc) |
Dimensions inverter (BxHxW) |
216 x 420 x 480 mm 216 x 420 x 550 mm (including projection) ISQ20-MFC-19": 482 x 174 x 315 mm |
216 x 420 x 480 mm 216 x 420 x 550 mm (including projection) ISQ20-MFC-19": 482 x 174 x 315 mm |
216 x 420 x 480 mm 216 x 420 x 550 mm (including projection) ISQ20-MFC-19": 482 x 174 x 315 mm |
216 x 420 x 480 mm 216 x 420 x 550 mm (including projection) ISQ20-MFC-19": 482 x 174 x 315 mm |
Weight transformer |
--- |
--- |
IT-60X: approx 16 kg TRM3: approx 45 kg MT-40X-530: approx 63 kg |
IT-113: approx 25,5 kg |
Dimensions transformer (BxHxW) in mm |
--- |
--- |
TRM3: 360 x 150 x 185 IT-60X: 284 x 110 x 170 MT-40X-530: 732 x 92 x235 |
IT-113: 420 x 125 x 230 |