IS800 AMY-Global Version |
IS-1400 AMY-Global Version |
Maximum primary output current (peak) |
1400 amps @ 3% |
4000 amps @ 12% |
Settings - Constant current |
0.05 - 80.0 kA | 1.00-260 kA |
Settings - Constant power |
0.05-120 kW |
0.50-390 kW |
Settings - Constant voltage |
0.20-9.99 V |
0.20-9.99 V |
Settings - Fixed pulse |
10.0-99.9% |
10.0-99.9% |
Weld monitors - Current |
0.0-99.9 kA |
0.0-300.0 kA |
Weld monitors - Power |
000.0-999.9 kW |
000.0-999.9 kW |
Weld monitors - Voltage |
0.00-9.99 V |
0.00-9.99 V |
Weld monitors - Pulse % |
10.0 - 100.0% |
10.0 - 100.0% |
Power source |
380 - 480 VAC, Three Phase, 50/60 Hz, +- 10% |
380 - 480 VAC, Three Phase, 50/60 Hz, +- 10% |
Output frequency |
600 - 1000 HZ |
600 - 100 HZ |
Control modes |
Primary constant current control, Primary limit control, Secondary RMS control, Power RMS control, Voltage control, Pulse % control |
Primary constant current control, Primary limit control, Secondary RMS control, Power RMS control, Voltage control, Pulse % control |
Number of schedules |
255 (Selectable by pendant or external I/0) |
255 (Selectable by pendant or external I/0) |
Time settings: Squeeze delay |
0000-9999 (ms) / 0000-9999 (CYC) |
0000-9999 (ms) / 0000-9999 (CYC) |
Time settings: Squeeze |
0000-9999 (ms) / 0000-9999 (CYC) |
0000-9999 (ms) / 0000-9999 (CYC) |
Time settings: Upslope |
000-999 (ms) / 00-50 (CYC) |
000-999 (ms) / 00-50 (CYC) |
Time settings: Weld |
000-999 (ms) / 00-50 (CYC) | 000-999 (ms) / 00-50 (CYC) |
Time settings: Cool |
0000-9999 (ms) / 0000-9999 (CYC) |
0000-9999 (ms) / 0000-9999 (CYC) |
Time settings: Down slope |
000-999 (ms) / 00-50 (CYC) |
000-999 (ms) / 00-50 (CYC) |
Time settings: Hold |
00000-20000 (ms) / 00000-00999 (CYC) |
00000-20000 (ms) / 00000-00999 (CYC) |
Time settings: Off time |
0 or 0010 - 9990 (ms) / 0000 - 0099 (CYC) |
00000-20000 (ms) / 00000-00999 (CYC) |
Time settings: Pulsation setting |
01-19 (settable for WELD 1 to WELD 3, respectively |
01-19 (settable for WELD 1 to WELD 3, respectively |
Transformer turns ration |
1.0-199.9 |
01-19 (settable for WELD 1 to WELD 3, respectively |
Valve setting |
Up to 6 valves - including proportional valve |
Up to 6 valves - including proportional valve |
Control gain (GAIN) |
1-9 | 1-9 |
Step-up/-down (STEPPER COUNT) |
STEP 1-9 (9 steps), UP (down) ratio (RATIO) 50-200%, Counter setting (COUNT) 0000-9999 |
STEP 1-9 (9 steps), UP (down) ratio (RATIO) 50-200%, Counter setting (COUNT) 0000-9999 |
Weld count monitor (PRESENT COUNT) |
0000-9999 |
0000-9999 |
External communication |
RS-232 (single or bi-directional) |
RS-232 (single or bi-directional) |
Program protect |
Programming protected when active | Programming protected when active |
EU Certification |
CE compliant | CE compliant |
WEIGHT & DIMENSIONS |
Dimensions L x W x H |
800 x 800 x 2000 mm | 800 x 800 x 2000 mm |
Weight |
250 kg | 300 kg |
Options |
RS-485 communications (RS-232 standard), Isolation contactors, MG Weld monitors, Cable throughput top cabinet |